All grade guides — one page, every alloy we cover
Browsing for a grade? The full library of per-grade technical guides is on one list.
Open the listFerralium 255 is the duplex grade that was designed around a different question. Where 2205 and 2507 chase higher and higher pitting resistance, 255 keeps 25 % chromium and 3.5 % molybdenum but adds 1.5-2.5 % copper on purpose, buying resistance to dilute sulphuric and phosphoric acid that the standard duplex grades simply do not have. This guide collects the ASTM minima, the physical data, the PREN arithmetic that decides whether a heat qualifies as super duplex at all, and the purchasing checks we run before shipping S32550 plate, bar, forgings and pump components.

Ferralium 255 (UNS S32550, W.Nr 1.4507, X2CrNiMoCuN25-6-3, ASTM A182 grade F61) is a 25 % chromium duplex stainless steel with roughly 45-55 % ferrite and 45-55 % austenite, strengthened by nitrogen and modified by an intentional copper addition of 1.5-2.5 %. It was patented by Langley Alloys in 1968 and is generally credited as the first nitrogen-bearing super duplex, which is why the trade name is still more widely recognised than the UNS number.
The copper is the whole point. In a chloride environment 255 behaves like a mid-range super duplex; in a dilute reducing acid — sulphuric, phosphoric, many organic acids — it behaves noticeably better than 2205 or 2507, because copper raises the potential at which the passive film breaks down in those specific media. That combination of 550 MPa yield, PREN 38-41 and acid resistance is why the grade survives commercially in slurry pumps, valve trim, phosphoric acid plants and hydrometallurgy, where a 904L impeller would be too weak and a 2507 impeller would corrode.
Think of the family as a ladder rather than a ranking: 2205 (PREN ≈ 35, 450 MPa yield, no copper) → Ferralium 255 (PREN 38-41, 550 MPa, 1.5-2.5 % Cu) → 2507 (PREN 41-43, 550 MPa, higher nitrogen) → Zeron 100 (PREN ≈ 40-42, tungsten plus copper). Each step buys one specific property and pays for it in price, availability and welding discipline.
Heat analysis per ASTM A240 for UNS S32550 (wt %):
| Element | Content (wt %) | What it does in 255 |
|---|---|---|
| Chromium (Cr) | 24.0-27.0 | Passive film former; sets the base pitting resistance and the oxidation limit |
| Nickel (Ni) | 4.5-6.5 | Balances the austenite/ferrite ratio at roughly 50/50; low Ni is deliberate — it is what keeps the alloy duplex rather than austenitic |
| Molybdenum (Mo) | 2.9-3.9 | Pitting and crevice resistance, plus general corrosion resistance in reducing media |
| Copper (Cu) | 1.50-2.50 | The design intent: raises resistance in dilute sulphuric and phosphoric acid and improves erosion-corrosion behaviour in slurries |
| Nitrogen (N) | 0.10-0.25 | Solid-solution strengthening (most of the 550 MPa yield) and fast austenite reformation in the weld HAZ |
| Carbon (C) | 0.04 max | Kept low to limit carbide precipitation; note this is looser than the 0.030 max of 2205/2507 |
| Manganese (Mn) | 1.50 max | Austenite former and deoxidation; high Mn is not wanted in seawater duty |
| Silicon (Si) | 1.00 max | Deoxidation; excessive Si promotes intermetallic phases |
| Phosphorus / Sulphur (P / S) | 0.040 / 0.030 max | Residuals. The 0.030 % S ceiling is generous — offshore specifications usually tighten it to 0.010 % |
| Iron (Fe) | Balance | Matrix |
Two certification traps are worth knowing before you release a heat.
First, EN 1.4507 is not the same window as A240. EN 10088-3 describes 1.4507 as Cr 24-26, Ni 6-8, Mo 3-4, N 0.20-0.30, Cu 1-2.5, C 0.03 max. A240 allows Ni 4.5-6.5 and N 0.10-0.25. A heat can only carry both certificates if it lands in the overlap — Ni 6.0-6.5 and N 0.20-0.25 — which means a "dual certified" plate is a narrower, more expensive heat than either single specification requires. If a supplier offers dual certification at the price of a plain A240 plate, ask for the heat analysis rather than the grade line on the certificate.
Second, the low-sulphur requirement is not cosmetic. Sulphur improves machinability but manganese sulphide inclusions are preferred pitting sites. For pump and seawater duty we default to S ≤ 0.010 % even though A240 permits 0.030 %.
Minimum values required by the ASTM product specifications, with typical mill-certificate ranges in brackets:
| Product form | 0.2 % yield | Tensile strength | Elongation (50 mm) | Hardness |
|---|---|---|---|---|
| Plate / sheet / strip — ASTM A240, annealed | ≥ 550 MPa | ≥ 760 MPa | ≥ 15 % | ≤ 302 HBW or ≤ 32 HRC |
| Bar / rod — ASTM A276 | ≥ 550 MPa | ≥ 760 MPa | ≥ 15 % | ≤ 302 HBW |
| Forgings / flanges — ASTM A182 F61 | ≥ 550 MPa | ≥ 760 MPa | ≥ 15 % | ≤ 302 HBW |
| Tube — ASTM A789 / A790 | ≥ 550 MPa | ≥ 760 MPa | ≥ 15 % | ≤ 302 HBW |
| Typical mill values, solution annealed | 586-650 MPa | 790-880 MPa | 25-28 % | ≤ 270 HBW |
| 255-SD50 (producer grade, section ≤ 300 mm) | ≥ 586 MPa guaranteed | ≥ 800 MPa | ≥ 25 % | — |
Watch the datasheets: 485 MPa / 690 MPa / 25 % is often quoted for "255" and it is not the ASTM A240 requirement. Those figures come from cast or proprietary product data. If your purchase order says ASTM A240 UNS S32550, the enforceable numbers are 550 / 760 / 15 % and 302 HBW — put them on the order and reject anything below.
Notes that matter in design:
Typical values from producer data compiled in the IMOA duplex guide; they are reference values, not ASTM requirements.
| Property | Value |
|---|---|
| Density | 7.82 g/cm³ (some sources 7.80) |
| Melting range | ≈ 1,400-1,450 °C (some sources 1,390-1,440 °C) |
| Thermal conductivity, 20 °C | 14.3 W/m·K |
| Thermal conductivity, 100 °C / 200 °C / 300 °C | 16.4 / 18.6 / 19.1 W/m·K |
| Specific heat capacity | 488 J/kg·K |
| Thermal expansion, 20-100 °C | 12.1 ×10⁻⁶ /K |
| Thermal expansion, 20-200 °C / 20-300 °C / 20-400 °C | 12.6 / 13.0 / 13.3 ×10⁻⁶ /K |
| Young's modulus, 20 °C | 210 GPa |
| Young's modulus, 100 °C / 300 °C / 500 °C | 200 / 192 / 170 GPa |
| Electrical resistivity | 0.84 µΩ·m |
| Magnetic behaviour | Ferromagnetic — both phases are magnetic, unlike 316L or 904L |
| Ferrite content | ≈ 45-55 % (NACE requires 35-65 %) |
Three practical consequences. The thermal expansion is about 30 % higher than carbon steel, so dissimilar-metal welds and long pipe runs need the expansion loops you would give a 304 line, not a carbon steel one. The thermal conductivity is roughly half that of carbon steel, which makes 255 prone to local overheating under a torch or a poor grinding pass. And the magnetic response is normal: a magnet test tells you nothing about whether the heat is correct, and a fabricator who "demagnetises" the plate is solving a problem that does not exist.
PREN for 255 is calculated as Cr + 3.3 Mo + 16 N (no tungsten in this grade):
The ASTM A240 composition window, taken at its minima, computes to a PREN of 35.2 — the same pitting resistance as 2205, not a super duplex at all. If your project specification, NORSOK M-630 clause or end-user datasheet calls for "super duplex", the purchase order must state "PREN ≥ 40, calculated from the heat analysis and reported on the mill certificate". Without that sentence you can legally receive a heat that is 5 points below the grade's reputation.
What the copper actually does:
Where not to use it: strongly oxidising acids such as nitric, hot concentrated sulphuric acid, and any stream where free halogens are present. In those media the copper addition is at best neutral and the duplex microstructure is at worst a liability.
Duplex stainless is not a high-temperature material, and 255 is no exception. Three windows matter:
| Window | What happens | Design consequence |
|---|---|---|
| −46 to +300 °C | Normal service range; toughness and corrosion resistance stable | Pressure duty up to about 300 °C. ASME BPVC Section VIII Div. 1 lists duplex grades only to 315 °C — verify the edition and the exact grade line before designing above 300 °C |
| 300-500 °C (fastest ≈475 °C) | Spinodal decomposition of the ferrite ("475 °C embrittlement") | Hardness and the ductile-brittle transition rise. A part that passed 45 J at −46 °C at delivery can fail it after a long hold in this band |
| 600-950 °C (fastest 800-850 °C) | Sigma and chi phase precipitation | Catastrophic loss of toughness and corrosion resistance. This is why annealing runs at ≥1,040 °C with rapid cooling, why no post-weld heat treatment is ever specified, and why hot-formed parts need a full re-anneal |
If the duty needs more than 300 °C, the answer is not "a better duplex" — it is a different family: 904L or Alloy 20 for corrosion at moderate temperature, 310S/800H for oxidation, or a nickel alloy for both. Pushing 255 past 300 °C usually ends in a failed impact test at the next shutdown inspection.
Low temperature is more forgiving: duplex retains useful toughness to about −50 °C, and impact testing at −46 °C is standard offshore practice. It is not a cryogenic material — for LNG or liquid nitrogen duty, use austenitic 304L/316L or an aluminium alloy.
| Grade | PREN | Yield min | Cu | Indicative cost vs 2205 | Choose it when |
|---|---|---|---|---|---|
| 2205 (S32205) | 34-36 | 450 MPa | none | 1.0 | General chloride duty, ambient seawater, cost-driven projects with no acid component |
| Ferralium 255 (S32550) | 38-41 | 550 MPa | 1.5-2.5 % | ≈ 1.4-1.7× | Dilute sulphuric or phosphoric acid plus chlorides and abrasion: pumps, valve trim, agitators, hydromet |
| 2507 (S32750) | 41-43 | 550 MPa | none | ≈ 1.5-1.8× | Maximum pitting/crevice resistance, hot seawater, heavy weld fabrication (0.27 N stabilises the HAZ better) |
| Zeron 100 (S32760) | 40-42 (W credited) | 550 MPa | 0.5-1.0 % | ≈ 1.8-2.2× | Sour service and hot seawater where a tungsten-bearing super duplex is named |
| 904L (N08904) | 34-36 | 220 MPa | 1.2-2.0 % | ≈ 2.0-2.5× | Welded acid equipment needing ductility and no 475 °C risk; strength is not the driver |
| Alloy 20 (N08020) | 26-31 | 241 MPa | 3-4 % | ≈ 2.5-3.0× | Hot sulphuric acid with chlorides; cast pump bodies and valve trim in fertiliser plants |
Cost multiples are indicative and move with the nickel, molybdenum and copper surcharges — treat them as an order-of-magnitude guide for early-stage selection, not as a quotation.
The substitution trap. F61 (255) and F53 (2507) sit next to each other in ASTM A182 and are frequently swapped by traders. They are not interchangeable. Supplying F53 against an F61 order deletes the copper and therefore the acid resistance the design was based on — that requires an engineering deviation, which in fertiliser and hydromet projects is rarely granted. Supplying F61 against an F53 order may be technically tolerable for plain chloride duty, but the PREN can fall below 40 and disqualify the alloy under NORSOK M-630, so it needs buyer approval plus heat-by-heat PREN verification.
Fast field test: 255 contains 1.5-2.5 % copper and 2507 does not. A handheld XRF or OES reading that shows no copper, on a part stamped F61, is proof of substitution — and it takes thirty seconds. We run this check on every 255 shipment before packing.
| Industry | Typical 255 components | Why 255 rather than 2205 or 2507 |
|---|---|---|
| Pulp & paper pumps | Impellers, casings, wear rings, shaft sleeves, stock pumps | Acid + chloride + abrasive stock: the copper helps in the reducing acid, the duplex structure resists cavitation |
| Phosphoric acid / fertiliser | Slurry pumps, agitators, reactor internals, transfer piping, heat-exchanger tubes | Wet-process acid carries chlorides and solids; 904L is too weak, 2507 corrodes in the reducing acid |
| Dilute sulphuric acid & hydrometallurgy | Mixer-settler internals, SX-EW pumps, laterite leach slurry lines, autoclave flash vessels | Documented service history in Cu-bearing duplex; erosion-corrosion resistance in slurries |
| Seawater & desalination | RO high-pressure pump bodies, brine pumps, firewater pump casings, valve bodies | Ambient seawater with 550 MPa yield; step up to 2507 above ~40-50 °C or in chlorinated crevices |
| Flue-gas desulphurisation & mining | Limestone slurry pumps, hydrocyclones, chutes, agitator shafts | Abrasion plus acidic chloride condensate — the combination that wears out 2205 quickly |
| Oil & gas (moderate sour) | Valve bodies and trim, small forgings, flowline components | NACE-qualified when ferrite 35-65 % and ≤28 HRC; for high H₂S partial pressure use Zeron 100 or 2507 |
| Marine hardware | Shafting sleeves, stern-gland components, fasteners above the waterline | Strength and corrosion in one piece; not for immersed high-stress shafts where 2507 is preferred |
The pattern is consistent: 255 wins where a pump or valve has to survive acid, chloride and solids at the same time. Where there is no acid, 2205 is cheaper and perfectly adequate; where there is no abrasion but extreme chloride, 2507 is better.
| Product form | Standard | Notes |
|---|---|---|
| Plate, sheet, strip | ASTM A240 / ASME SA-240 | Solution annealed ≥1,040 °C, rapid cooling, pickled or descaled |
| Bar and rod | ASTM A276, A479 | A479 for pressure-retaining bar stock in vessels |
| Forgings, flanges, fittings stock | ASTM A182 grade F61 | F61 is the correct marking; F53 is 2507 |
| Seamless and welded tube | ASTM A789 / A790 | Check that the tube specification explicitly lists S32550 — not all editions do |
| Pipe fittings | ASTM A815 (UNS S32550) | Butt-weld and forged fittings |
| European designation | EN 10088-2 / -3, 1.4507 | Narrower window than A240 — see the composition section |
| Chinese designation | GB/T 21833, 03Cr25Ni6Mo3Cu2N (S25554) | Common for domestic pump castings and forgings |
| Japanese designation | JIS SUS 329J4L | — |
| Sour service | NACE MR0175 / ISO 15156-3 | Ferrite 35-65 %, hardness ≤28 HRC, heat treated per the standard |
| Offshore procurement | NORSOK M-630 (MDS), M-650 qualification | PREN ≥ 40 is normally written into the MDS — this is where the A240 minimum fails |
Forms we supply: plate 3-60 mm, round bar 12-250 mm, forged rings, blocks, flanges and valve bodies to drawing, seamless tube, and machined pump components. Ferralium 255 is a Langley Alloys trademark: if your purchase order names the trademark rather than UNS S32550, either the mill must be Langley or you need a documented equivalence approval before shipment.
255 welds like a super duplex, which is to say: easily, provided you respect the phase balance and the cooling rate.
Machining is where most first-time users lose money. 255 work-hardens faster than 316L, so light cuts and dwelling are the enemy: use sharp carbide, positive rake, heavy feed and constant engagement, and never let the tool rub. Drilling deep holes needs a peck cycle and generous coolant. Cold forming is possible but springback is roughly double that of austenitic stainless because of the 550 MPa yield — over-bend accordingly, and anneal between severe operations.
| # | Requirement to write on the PO | Why |
|---|---|---|
| 1 | UNS S32550, ASTM A240 (or A276 / A182 F61 / A789), solution annealed ≥1,040 °C, rapid cooled | Locks the grade and the heat treatment; a slow-cooled plate is the most common failure mode |
| 2 | PREN ≥ 40 calculated from the heat analysis and reported on the certificate | The composition minima only compute to 35.2; without this line the "super duplex" claim is unenforceable |
| 3 | Hardness ≤ 270 HBW (≤ 28 HRC if NACE MR0175 applies), tested on every piece | The cheapest proxy for correct quench and for sour-service compliance |
| 4 | Ferrite 35-65 % by point count, reported per heat | Required by NACE; also catches unbalanced heats that weld badly |
| 5 | Charpy 45 J average at −46 °C (three specimens) for low-temperature or offshore duty | Not an A240 requirement — must be bought explicitly |
| 6 | EN 10204 3.1 certificate, PMI with copper reported, ASTM G48 Method A on request | Copper is the discriminator against 2507; G48 catches sigma and wrong annealing |
The single most useful check on a 255 delivery is also the cheapest: an XRF reading of copper. 1.5-2.5 % Cu confirms 255; 0 % Cu with a matching chromium level means you have been shipped 2507, and 0 % Cu with lower chromium means 2205. Neither will perform in the acid service the part was designed for.
Lead times are realistic at 30-45 days for plate and bar from mill stock plus processing, and 45-70 days for forged or machined pump components. Anyone quoting 255 from stock in a wide size range is usually quoting a substitute — ask for the heat number before you celebrate the delivery date.
We supply UNS S32550 plate, bar, forged rings, flanges and machined pump and valve components against ASTM A240 / A276 / A182 F61, with EN 10204 3.1 certificates as standard. Every lot is PMI-verified with copper reported, hardness-tested, and — where the specification calls for it — impact tested at −46 °C and checked to ASTM G48.
Typical lead time is 30-45 days for plate and bar, 45-70 days for forged and machined parts. If you are replacing a 2507 or 2205 component because of an acid-side corrosion failure, send us the medium, concentration, temperature and the failed part's condition — we will tell you whether 255 is genuinely the right step, or whether the duty actually needs Alloy 20 or a nickel alloy.
No. Both are 25 % Cr duplex with about 550 MPa yield, but 255 carries 1.5-2.5 % intentional copper and a lower nitrogen range, giving PREN 38-41 against 41-43 for 2507. The copper buys dilute-acid resistance; 2507 buys chloride pitting margin and better HAZ stability when welding thick sections. The forging grades are F61 and F53 respectively and are not interchangeable on a purchase order.
Yes. Both the ferrite and the austenite in a duplex steel respond to a magnet, and the ferrite content of about 50 % makes the response strong. Magnetism is not an indication of a wrong grade or of heat damage.
About 300 °C for pressure duty. Between 300 and 500 °C the ferrite embrittles (fastest near 475 °C) and between 600 and 950 °C sigma phase forms. ASME Section VIII Div. 1 lists duplex grades only up to 315 °C, so a design above 300 °C needs a code check rather than a catalogue value. For hotter corrosive duty, move to 904L, Alloy 20 or a nickel alloy.
Because ASTM A240 sets composition minima, not a PREN minimum. At 24.0 % Cr, 2.9 % Mo and 0.10 % N the formula gives 35.2. A heat inside the specification can therefore be ordinary duplex in performance. Write 'PREN ≥ 40 calculated from heat analysis' on the order and require it on the mill certificate.
Often yes, and with more than double the yield strength — but the two are not equivalent. 904L is austenitic, welds and forms more easily and has no 475 °C embrittlement issue; 255 is stronger and cheaper per unit strength but sensitive to heat treatment discipline. Check the actual concentration and temperature against an isocorrosion chart for both grades before switching, especially above 60 °C.
No — and you should not. Any hold in the 600-950 °C range precipitates sigma phase and destroys toughness and corrosion resistance. Correct practice is controlled heat input (0.5-2.5 kJ/mm), interpass below 150 °C, nitrogen-purged root, and pickle/passivate afterwards. If a specification demands stress relief, propose full solution annealing at ≥1,040 °C with rapid cooling instead.
Read the copper. 255 contains 1.5-2.5 % Cu; 2507 contains none. A handheld XRF or a laboratory OES check takes seconds and is the definitive field test. Confirm the marking is F61 (255) and not F53 (2507) as well, and ask for the heat analysis rather than the grade line on the certificate.
Send us your drawing or specification for a quotation — we reply within one business day.
Buy this grade as: Plate · Round bar · Seamless tube · Flanges