All grade guides — one page, every alloy we cover
Browsing for a grade? The full library of per-grade technical guides is on one list.
Open the list310S is the standard answer when a part has to sit in a furnace at 1,000–1,150 °C in air and keep its shape: 25 % chromium for a scaling-resistant oxide, 20 % nickel to hold a fully austenitic structure at temperature, and low carbon so welds do not sensitize. 310H is the same steel with carbon deliberately raised to 0.04–0.10 % for creep strength above roughly 600 °C. This guide covers both, the carbon decision between them, the sigma-phase window that catches most first-time users, and the fabrication rules that keep furnace parts from cracking in service.

310S (UNS S31008, W.Nr 1.4845, JIS SUS310S, GB 06Cr25Ni20) is a high-chromium, high-nickel austenitic stainless steel — nominally 25 % Cr, 20 % Ni, carbon capped at 0.08 % — designed for service where oxidation resistance and structural stability at temperature matter more than room-temperature strength. It is the workhorse heat-resistant grade of the 300 series: it resists scaling in air to about 1,150 °C in continuous duty, stays fully austenitic (so it does not embrittle by the ductile-brittle transition that limits ferritic heat-resistant steels), and welds with ordinary stainless practice. 310H (UNS S31009) is the same composition with carbon specified at 0.04–0.10 % instead of 0.08 % max; the higher carbon raises creep and rupture strength above roughly 550–600 °C, at the cost of somewhat greater carbide precipitation. The basic 310 grade (UNS S31000) allows carbon up to 0.25 % and is essentially obsolete for new work.
Think of the family as a ladder by temperature: 309S (22 Cr / 13 Ni) to about 980 °C, 310S to about 1,050–1,100 °C continuous, 310H where creep design governs above 600 °C, and 314 (25/20 with ~2 % Si) or 253MA where cyclic scaling or higher creep strength is needed. Above roughly 1,150 °C, or in sulphur-bearing or reducing atmospheres, the answer moves to nickel-base grades — 600, 601 or 693.
| Element | 310S (S31008) | 310H (S31009) | Why it matters |
|---|---|---|---|
| Chromium (Cr) | 24.0–26.0 | 24.0–26.0 | Forms the Cr2O3 scale that gives oxidation resistance to ~1,150 °C |
| Nickel (Ni) | 19.0–22.0 | 19.0–22.0 | Stabilizes austenite, keeps high-temperature toughness, resists chloride SCC |
| Carbon (C) | 0.08 max | 0.04–0.10 | The only real difference: carbon raises creep strength and carbide volume |
| Silicon (Si) | 1.50 max | 1.50 max | Improves scaling resistance; higher Si (314) extends it further |
| Manganese (Mn) | 2.00 max | 2.00 max | Austenite former, deoxidation |
| Phosphorus / Sulphur | 0.045 / 0.030 max | 0.045 / 0.030 max | Residuals; sulphur affects weldability |
| Iron (Fe) | Balance | Balance | Matrix |
310S and 310H are metallurgically the same steel separated by a carbon band. A mill certificate for 310S must show C ≤ 0.08 %; for 310H, C between 0.04 and 0.10 %. Because both are 25/20, a PMI gun cannot tell them apart — the carbon value on the certificate is the only proof, so always state S31008 or S31009 on the purchase order and check the heat analysis on arrival.
Room-temperature floors are identical for the two grades; the difference appears only in elevated-temperature design allowables.
| Grade / form | 0.2 % yield | Tensile strength | Elongation | Hardness |
|---|---|---|---|---|
| 310S plate — ASTM A240 (annealed) | ≥ 205 MPa [230–290] | ≥ 515 MPa [550–650] | ≥ 40 % [45–55] | ≤ 95 HRB (≈ 150–180 HB typical) |
| 310S bar — ASTM A276 (annealed) | ≥ 205 MPa | ≥ 515 MPa | ≥ 40 % | ≤ 95 HRB |
| 310S pipe — ASTM A312 / A213 (annealed) | ≥ 205 MPa | ≥ 515 MPa | ≥ 35–40 % | — |
| 310H plate — ASTM A240 (annealed) | ≥ 205 MPa | ≥ 515 MPa | ≥ 40 % | ≤ 95 HRB |
| Cold-worked sheet / strip | agreed on order | 700–900 MPa | 15–30 % | — |
Three practical points. First, 205 MPa yield is low by modern standards — these grades are selected for temperature capability, not for load-bearing efficiency at room temperature; if you need strength at 20 °C, use duplex or a precipitation-hardening grade. Second, 310H does not give higher room-temperature values: its benefit is entirely in the creep and rupture regime, where ASME II-D tabulates higher allowable stresses for 310H than for 310S above roughly 550–600 °C. Third, the annealed condition is soft and ductile, which is what you want for formed furnace furniture, but cold work from bending or straightening raises yield quickly and can leave residual stress that matters in cyclic service.
| Property | Typical value |
|---|---|
| Density | 7.98 g/cm³ (some sources 7.95 — within normal product tolerance) |
| Melting range | ≈ 1,400–1,450 °C |
| Thermal conductivity | ≈ 14.2 W/m·K at 100 °C; rises to ≈ 18–19 W/m·K at 500 °C |
| Specific heat (20 °C) | ≈ 500 J/kg·K |
| Mean expansion (20–100 °C) | ≈ 15.9 ×10⁻⁶ /K (≈ 16.5 ×10⁻⁶ /K average over 20–1,000 °C) |
| Modulus of elasticity (20 °C) | ≈ 200 GPa |
| Electrical resistivity (20 °C) | ≈ 0.78 µΩ·m |
| Magnetic behaviour | Non-magnetic when annealed; slight ferromagnetism after heavy cold work or after sigma-phase formation |
Do not skip the expansion number. At ~16 ×10⁻⁶ /K, 310S expands about a third more than carbon steel and 10–15 % more than 304, while its thermal conductivity is only about a third of carbon steel's. The combination — high expansion, poor conduction — produces thermal gradients and thermal stress, and it is the single most common reason furnace fixtures and radiant tubes crack: not loss of strength, but thermal fatigue from restrained expansion.
Atmosphere rule of thumb: clean oxidizing air, continuous, no load → 310S to 1,100–1,150 °C. Load-bearing above 600 °C → 310H. Thermal cycling with scale spall, or sulphur in the gas → leave the 300 series and go to 601 or 693. Reducing or carburizing atmospheres are never 310S territory, whatever the temperature.
This is where most 310S failures originate, and it is entirely predictable. Between roughly 600 and 900 °C — fastest around 750–850 °C — the high chromium content that makes 310S heat-resistant also makes it willing to precipitate sigma phase, a hard, brittle intermetallic at the grain boundaries. The consequences are a sharp drop in room-temperature ductility and impact toughness, a slight rise in magnetism, and reduced corrosion resistance. A furnace part that ran happily at 1,050 °C for years can shatter on cooldown after a spell in the sigma window, or crack during a shutdown.
| Temperature band | What happens | Design implication |
|---|---|---|
| 425–860 °C | Sensitisation: chromium carbides precipitate at grain boundaries, chromium-depleting the adjacent metal | Avoid slow cooling through this band after annealing or welding; use low-carbon 310S rather than high-carbon 310 |
| 600–900 °C (peak 750–850 °C) | Sigma phase forms; toughness and ductility fall progressively over hundreds to thousands of hours | Do not design long-term service or slow-cool through this band; 310H is more susceptible than 310S but is used there only when creep governs and toughness is not needed |
| Above ~950 °C | Sigma dissolves; carbides go back into solution | Solution anneal at 1,040–1,150 °C and water-quench to restore ductility after service exposure |
If a 310S part must operate in the 600–900 °C band, tell us at the enquiry stage. The usual answers are: accept a lower design stress and inspect for toughness, switch to a grade that does not form sigma as readily (309S is no better; 800H or 601 are), or design for replacement. Never rely on a room-temperature tensile test to prove a sigma-embrittled part is fit for purpose — impact testing is the only meaningful check.
| Industry | Typical 310S / 310H components | Why this grade |
|---|---|---|
| Heat treatment & furnaces | Muffles, retorts, annealing boxes, baskets, trays, fixtures, radiant tubes, fan shafts, roller rails | Scaling resistance to ~1,150 °C plus structural stability — no phase transformation on cycling |
| Boilers & power | Superheater and reheater tube supports, hangers, spacers, burner nozzles, soot-blower parts | Creep strength (310H) and oxidation resistance in flue gas |
| Cement, lime & ceramics | Kiln internals, preheater cyclones, burner tips, kiln nose rings, saggar and kiln furniture | Hot strength and resistance to alkali/oxide dust at 900–1,100 °C |
| Petrochemical & refining | Furnace tube supports, transfer-line hangers, coke-drum internals, catalyst-bed grids | High-temperature strength with weldability |
| Chemical processing | Nitric-acid equipment, high-temperature reactor internals, catalyst supports, thermocouple protection tubes | Nitric acid and oxidizing service plus heat |
| Waste incineration & environmental | Grate bars, ash-handling parts, flue ducting, thermal-oxidizer internals | Oxidation resistance at temperature; not for the aggressive HCl/alkali zones |
| Automotive & aerospace ground equipment | Exhaust manifolds for heavy-duty and stationary engines, heat shields, test-rig ducting | Thermal fatigue resistance in cyclic hot gas |
| Cryogenic & special | LNG and cryogenic vessel internals, superconducting magnet structure | Retains toughness at low temperature — no DBTT |
| Product form | ASTM / ASME specification |
|---|---|
| Plate, sheet, strip | ASTM A240 / ASME SA240 |
| Bar, rod, wire | ASTM A276 / A479 |
| Seamless and welded pipe | ASTM A312 / ASME SA312 |
| Seamless and welded tube | ASTM A213 / A249 / A269 |
| Welded fittings | ASTM A403 WP310 |
| Castings | ASTM A351 CK20 / A297 HK |
| Welding consumables | ER310 (AWS A5.9), E310 (A5.4); ERNiCr-3 for dissimilar joints |
| European designation | W.Nr 1.4845, X8CrNi25-21 |
| Asian designations | JIS SUS310S, GB/T 06Cr25Ni20, KS STS310S |
Note the W.Nr trap: 1.4845 covers both 310S and 310H because the European standard no longer separates them by carbon band in the same way as ASTM. If your specification is written in EN terms, add the UNS number and the carbon range explicitly. 1.4841 is a different steel (314, with ~2 % Si) and is not interchangeable.
| Check | What to look for |
|---|---|
| Grade identity | UNS S31008 (310S) or S31009 (310H) stated on the PO and certificate — never just "310", which permits 0.25 % carbon |
| Carbon | 310S: ≤ 0.08 %; 310H: 0.04–0.10 %. This is the only way to distinguish the two — PMI cannot |
| Chromium / nickel | Cr 24.0–26.0 %, Ni 19.0–22.0 %; be suspicious of material sitting at the bottom of both ranges |
| Condition | Solution annealed, with the annealing temperature and cooling method stated |
| Grain size | For creep-critical 310H, agree a grain size (typically ASTM 4 or coarser) — fine grains creep faster |
| Intergranular test | ASTM A262 Practice E on request for welded assemblies in corrosive service |
| Certificates | EN 10204 3.1 plus PMI; UT for pressure-boundary plate; dimensional check to A480 |
| Surface | No embedded iron, no grinding burn; pickled finish for furnace parts that will be cycled |
We supply 310S and 310H as plate, sheet, bar, seamless and welded pipe, tube, fittings and machined furnace furniture, cut to size and, where needed, formed and welded to drawing. Stock sizes normally ship in 7–15 days; mill-rolled plate and heat-specific 310H orders run 30–45 days. Tell us the design temperature, the atmosphere (oxidizing, carburizing, sulphur-bearing), whether the part carries load and whether it cycles — those four answers decide between 310S, 310H, 309S, 314 or a nickel-base grade, and we would rather steer you to the right one before you buy than replace a cracked retort afterwards.
Order 310S for sheet, ducting and non-load-bearing parts and for anything welded that will see aqueous or mildly corrosive service — the lower carbon resists sensitisation. Order 310H when the part carries load above roughly 600 °C and the design is limited by creep: tube supports, hangers, radiant tubes, kiln internals. Room-temperature properties are the same, so the decision is purely about temperature and load.
About 1,150 °C in clean, dry, oxidizing gas under continuous duty, and about 1,035 °C where thermal cycling causes scale to spall. In load-bearing applications the limit is set by creep, not oxidation, and falls to roughly 900–1,000 °C depending on stress. Reducing, carburizing or sulphur-bearing atmospheres cut the usable temperature much further — in those cases move to 601 or 693.
No. Its PREN is only about 25 because it contains no molybdenum or nitrogen, so pitting and crevice corrosion start quickly in chloride water. For seawater use a 6 % Mo super-austenitic (254SMO, AL-6XN) or a duplex/super duplex grade.
It is non-magnetic in the annealed condition. Slight magnetism after heavy cold working or bending is normal and harmless. Strong magnetism on a part that has been in high-temperature service is a warning sign of sigma phase or of a wrong grade — check the certificate and consider impact testing.
No — and it usually should not get one. A stress relief in the 600–900 °C range would precipitate sigma phase and sensitise the heat-affected zone. The correct post-weld treatment, if any, is a full solution anneal at 1,040–1,150 °C with rapid cooling, which is impractical on large fabrications and therefore designed around.
309S (22 Cr / 13 Ni) is the cheaper step down, adequate to about 980 °C and often used for furnace supports that are not heavily loaded. 310S extends oxidation resistance to ~1,150 °C and is the default for 1,000–1,100 °C work. 314 adds about 2 % silicon for better scaling resistance and higher creep strength but is harder to weld and much less available.
Send us your drawing or specification for a quotation — we reply within one business day.
Buy this grade as: Plate · Round bar · Seamless tube · Flanges · Welding wire · Forged rings